Anti-legionella cycle

The anti-legionella cycle regularly heats the hot water cylinder to a higher temperature to kill off germs. You can clarify with your installer how often this is useful.

12345
Buffer cylinder and hot water cylinder
  1. Heat pump.
  2. Diverter valve: it directs the heating water either to the heating circuit or to the hot water.
  3. Buffer cylinder: balances out short-term differences between heat generated and heat used.
  4. Heating circuit with underfloor heating or radiators.
  5. Hot water cylinder: keeps the domestic water warm; occasionally, it is heated to a higher temperature for legionella protection.
Schematic. Not every system needs a buffer cylinder.

Legionella are bacteria that can multiply in warm, stagnant water. They are particularly dangerous when inhaled as a fine mist while showering. Many heat pumps therefore have a Legionella protection cycle: the cylinder is heated to a higher temperature at fixed intervals to kill off germs.

What applies to detached houses

  • The klimaaktiv Wegweiser (guide) refers to the Trinkwasserverordnung (Drinking Water Ordinance): temperature ranges between 25 and 45 °C, which promote the growth of pathogens, must be avoided. It specifies 55 °C as the target temperature before the tap.
  • The stricter hygiene standard for larger buildings (formerly ÖNORM B 5019, currently ÖNORM B 1921) requires, according to the guide, over 60 °C at the cylinder outlet and at least 55 °C in the pipes; detached and semi-detached houses are exempt.
  • The klimaaktiv Ratgeber Warmwasser (hot water guide) states that an outlet temperature of at least 50 °C must be achievable in single- and two-family homes.

Balancing efficiency and hygiene

Every extra degree in the cylinder costs money: according to klimaaktiv, heat losses increase by an average of around 1.6 % per degree. Short, well-insulated pipes without continuous circulation are the best prevention, as less water stands for long periods. After a holiday, klimaaktiv recommends heating the cylinder to over 60 °C once and flushing the pipes for a few minutes.

It is best to agree with your installer during handover how often and to what temperature your Legionella protection cycle should run.

All terms · Heat pump knowledge