Heat pump glossary
The most important terms you will encounter during planning, quoting and operation, explained briefly and clearly.
A
- Exhaust air heat pump
- An exhaust air heat pump uses residual heat from extracted indoor air via the ventilation system. This is only suitable for homes with a very low heating demand.
- Defrosting
- During defrosting, an air-source heat pump removes frost and ice from its outdoor heat exchanger. This uses a little energy and is just part of winter operation.
- Installation site and distance to property boundary
- There is no uniform minimum distance to the property boundary in Austria. State law, the device, the installation type and the sound level at the boundary all count.
- Expansion vessel
- The expansion vessel compensates for the expansion of heating water as it heats up. This keeps the pressure stable and prevents air from entering the system.
B
- Bivalence point
- The bivalence point is the outdoor temperature below which the heat pump alone is no longer sufficient and a second heat generator helps out.
- Domestic hot water heat pump
- A domestic hot water heat pump only heats your hot water. It is usually mounted directly on a cylinder and uses the heat from the indoor or outdoor air.
C
- COP (Coefficient of Performance)
- The COP indicates how much heat a heat pump generates from one kilowatt-hour of electricity: measured on a test bench, at a single operating point.
D
- Continuous operation (heat pump runs non-stop)
- If the heat pump runs for hours or almost continuously, this is usually normal. Warning signs are cold rooms, frequent immersion heater use and high electricity consumption.
- Dynamic electricity tariff
- With a dynamic electricity tariff, your energy price follows the stock exchange price. You need a smart meter for this, and the price risk lies with you.
E
- Efficiency class (ErP energy label)
- The EU energy label classifies heat pumps into efficiency classes. klimaaktiv recommends the highest available class at a 40 °C flow temperature.
- Individual room control
- With individual room control, each room regulates its own temperature. With a heat pump, its main job is to compensate for external heat gains, while the heating curve handles the rest.
- Energieausweis (energy performance certificate) and heating demand (HWB)
- The Heizwärmebedarf (heating energy requirement) in the Energieausweis (energy performance certificate) shows how much heat your house theoretically needs. It is a good initial indication of whether a heat pump is suitable.
- Energy management system (HEMS)
- A home energy management system automatically controls the heat pump, photovoltaics, storage unit and charging station, shifting consumption to cheaper times.
- Geothermal basket and trench collector
- Geothermal baskets and trench collectors extract geothermal energy from a smaller surface area than a horizontal ground loop. To compensate, they usually extend deeper into the ground.
- Expansion valve
- The expansion valve reduces the pressure of the liquid refrigerant. In doing so, it cools down and can absorb heat again in the evaporator.
F
- F-Gas Regulation
- EU Regulation 2024/573 gradually restricts fluorinated greenhouse gases. For new heat pumps, cut-off dates starting from 2027 apply depending on design and capacity.
- Surface heating (underfloor and wall heating)
- A surface heating system emits heat over large areas such as the floor or wall. It manages with low flow temperatures and is a good match for a heat pump.
- Horizontal collector (ground collector)
- A horizontal collector is a pipe network just below the surface of the ground, through which a geothermal heat pump extracts heat from the garden. It requires a lot of space.
- Fresh water station
- A fresh water station heats domestic hot water only when it is drawn off via a heat exchanger. The heat comes from a buffer cylinder containing heating water.
- Frost protection (glycol and frost protection valve)
- Frost protection prevents water from freezing in the heat pump's pipework. Common methods are glycol, the control unit's frost protection function, and anti-freeze valves.
G
- GWP (Global Warming Potential)
- The GWP value shows how much a refrigerant contributes to global warming if it escapes. CO2 has a value of 1; the lower, the better.
H
- Heat Pump Keymark
- The Heat Pump Keymark is a voluntary European certificate. Independent bodies verify whether a heat pump's performance specifications are accurate.
- Heating threshold temperature
- The heating threshold (Heizgrenze) is the outside temperature below which a house needs to be heated. In Austria, 12 °C is usually assumed, but it varies for each house.
- Heating curve
- The heating curve determines how warm the heating water should be at a given outdoor temperature. Correctly adjusted, it saves electricity while maintaining the same level of comfort.
- Heating load
- The heating load is the output in kilowatts that your house needs on the coldest day. The heat pump is sized according to this, not according to the old boiler.
- Heating element (electric auxiliary heater)
- The heating element is an auxiliary electric heater in the cylinder or appliance. It kicks in on very cold days, but only produces 1 kWh of heat from 1 kWh of electricity.
- Heating water (water quality)
- Heating water circulates in a closed circuit for years. Its quality plays a key role in preventing corrosion, limescale, sludge, and extending the system's lifespan.
- Calorific value (converting fuel into kWh)
- The calorific value tells you how many kilowatt-hours are contained in a litre of oil or kilogram of pellets. This lets you compare your consumption with a heat pump.
- High-temperature heat pump
- A high-temperature heat pump delivers higher flow temperatures than standard systems, for instance for older buildings with radiators. However, this comes at the expense of efficiency.
- Hybrid heating system (heat pump with boiler)
- A hybrid heating system combines a heat pump with a second heat generator, such as a pellet boiler. This is particularly useful at high flow temperatures.
- Low-loss header
- A hydraulic separator decouples the heat pump circuit from the heating circuits. It solves flow volume issues, but can mix the flow and return.
- Hydraulic balancing
- During hydraulic balancing, each heating circuit is adjusted so that it receives exactly the required amount of water. This allows for a lower flow temperature.
I
- Inverter and power modulation
- A modulating heat pump continuously adjusts its output to demand, usually via an inverter. This is more efficient than simply switching on and off.
J
- Seasonal Performance Factor (SPF)
- The seasonal performance factor shows how much heat your heat pump delivers over the entire year per kilowatt-hour of electricity. It is the most important key figure.
K
- Refrigerant
- The refrigerant is the substance that evaporates and liquefies again inside the heat pump, thereby transporting the heat from the source into the house.
- Cascade (multiple heat pumps)
- In a cascade system, several heat pumps work together as a single system. This provides greater flexibility and reliability, especially in large buildings.
- Combi storage tank and hygiene storage tank
- Combination and hygiene storage tanks keep heat for space heating and domestic hot water in a single vessel. For heat pumps, klimaaktiv usually advises other solutions.
- Cooling with the heat pump
- Many heat pumps can also cool in summer: passively via the ground or groundwater, or actively with the compressor running.
L
- Legionella protection cycle
- The anti-legionella cycle regularly heats the hot water cylinder to a higher temperature to kill off germs. You can clarify with your installer how often this is useful.
- Air-to-air heat pump
- An air-to-air heat pump extracts heat from the outside air and releases it directly into the indoor air. In most cases, this is a split air conditioning unit with a heating function.
- Air-to-water heat pump
- The air-to-water heat pump uses the outdoor air as a heat source to heat the heating water. It is the easiest type of heat pump to install.
M
- Monobloc heat pump
- With a monobloc heat pump, the entire refrigerant circuit is located in the outdoor unit. Only water pipes lead into the house, not refrigerant lines.
- Monovalent, monoenergetisch, bivalent
- The operating mode indicates whether the heat pump heats alone, an immersion heater kicks in, or a second heating system such as a boiler assists.
N
- Night setback
- With a night setback, the system heats less at night. With a heat pump, this usually brings little benefit because reheating in the morning reduces efficiency.
- Low-temperature radiator
- Low-temperature radiators emit enough heat even at low flow temperatures. It is often sufficient to replace individual critical radiators.
- Design outdoor temperature
- The design outdoor temperature is the cold rating used to calculate the heating load of your house. In Austria, it is fixed for each location.
P
- Photovoltaic self-consumption with a heat pump
- With a heat pump, you can use more of your own solar power yourself, especially for hot water. In the depths of winter, however, PV only covers a small portion.
- Test point A7/W35
- A7/W35 means: tested at 7 °C outdoor air and 35 °C heating water. The value shows a single operating point, not efficiency over the course of the year.
- Buffer tank
- A buffer cylinder is a water tank for heating water. With modern, modulating heat pumps in detached houses, it is often not needed at all.
R
- R290 (propane)
- R290 is propane used as a natural refrigerant. It has a very low global warming potential, but is flammable and therefore requires safety precautions.
- R32 (refrigerant)
- R32 is a fluorinated refrigerant with a GWP of 675. In many new heat pumps, it will no longer be permitted from 2027 due to EU rules.
- Seasonal space heating energy efficiency (ηs)
- ηs is the standardised heating efficiency over a heating season, expressed as a percentage. Because electricity generation is factored in, it is over 100%.
- Return temperature
- The return temperature is the temperature of the heating water flowing back to the heat pump from the radiators or underfloor heating.
S
- Sound pressure level
- The sound pressure level is the volume that reaches a specific location, such as the property boundary. It decreases with distance from the heat pump.
- Sound power level
- The sound power level indicates how much noise the heat pump itself emits, regardless of the location. It is listed in the data sheet and is suitable for comparison.
- SCOP (seasonal coefficient of performance)
- The SCOP is a standardised seasonal coefficient of performance for a standard climate. It is suitable for comparing devices, but does not tell you what your system will actually achieve.
- SG-Ready
- SG-Ready is a label for heat pumps with an interface through which they can process signals from the PV system, energy manager or grid.
- Brine-to-water heat pump (geothermal energy)
- The brine-to-water heat pump extracts heat from the ground via probes or collectors. It is more efficient than an air-source heat pump, but more complex.
- Grid operator blocking times
- With an interruptible heat pump tariff, the grid operator is allowed to temporarily switch off the heat pump. The system must be able to bridge these pauses.
- Split heat pump
- A split heat pump consists of an outdoor and an indoor unit connected by refrigerant lines. Installation requires specialist knowledge of refrigeration technology.
- Temperature differential (spread)
- The spread is the difference between flow and return temperature. It shows how much the heating water cools down in the house.
T
- Cycling
- Cycling means that the heat pump frequently switches on and off for short periods. This reduces efficiency and lifespan, and often indicates that the unit is too large.
- Deep drilling (geothermal probe)
- With deep drilling, a geothermal probe is inserted vertically into the ground. It requires little surface area and provides consistent heat all year round.
U
- U-value
- The U-value shows how much heat is lost through a building element. The lower it is, the better the wall, roof or window insulates.
- Circulation pump
- The circulating pump moves the heating water through pipes and heating surfaces. Modern, controlled pumps adjust automatically and use little electricity.
V
- Evaporator
- In the evaporator, the liquid refrigerant absorbs heat from air, ground or groundwater and turns into gas. It is the heat exchanger on the source side.
- Compressor
- The compressor increases the pressure of the gaseous refrigerant. This raises its temperature to a usable level.
- Condenser
- In the condenser, the hot refrigerant gas transfers its heat to the heating water, turning back into a liquid in the process.
- Flow rate
- The flow rate indicates how much heating water flows through the system per hour. The heat pump requires a minimum volume, otherwise it will not run properly.
- Flow temperature
- The flow temperature is the temperature of the heating water on its way to the heating surfaces. The lower it is, the more efficiently the heat pump operates.
W
- Heat meter
- A heat meter measures how much heat your heat pump delivers. Together with the electricity meter, this allows you to determine the actual seasonal performance factor (SPF).
- Heat pump tariff
- A heat pump tariff is a dedicated electricity tariff for the heat pump, often via an interruptible metering point. Whether it is worth it is a matter of calculation.
- Hot water cylinder (boiler)
- The hot water cylinder stores heated drinking water. It should be as large as necessary and as small as possible to keep heat losses to a minimum.
- Heat pump maintenance
- A heat pump requires little maintenance, but regular checks. For fluorinated refrigerants, a leak check may be mandatory.
- Water-to-water heat pump (groundwater)
- The water-to-water heat pump uses groundwater as a heat source. It is highly efficient, but requires wells and a water rights permit.
- Wasserrechtliche Bewilligung (water rights permit)
- Anyone using groundwater for a heat pump requires a wasserrechtliche Bewilligung (water rights permit). Geothermal energy is only affected in certain cases, in which case a notification is required.
- Weather-compensated control
- The weather-compensated control system adjusts the flow temperature according to the outside temperature. To do this, it requires an outdoor sensor and a heating curve.