Heat pump glossary

The most important terms you will encounter during planning, quoting and operation, explained briefly and clearly.

ABCDEFGHIJKLMNPRSTUVW

A

Exhaust air heat pump
An exhaust air heat pump uses residual heat from extracted indoor air via the ventilation system. This is only suitable for homes with a very low heating demand.
Defrosting
During defrosting, an air-source heat pump removes frost and ice from its outdoor heat exchanger. This uses a little energy and is just part of winter operation.
Installation site and distance to property boundary
There is no uniform minimum distance to the property boundary in Austria. State law, the device, the installation type and the sound level at the boundary all count.
Expansion vessel
The expansion vessel compensates for the expansion of heating water as it heats up. This keeps the pressure stable and prevents air from entering the system.

B

Bivalence point
The bivalence point is the outdoor temperature below which the heat pump alone is no longer sufficient and a second heat generator helps out.
Domestic hot water heat pump
A domestic hot water heat pump only heats your hot water. It is usually mounted directly on a cylinder and uses the heat from the indoor or outdoor air.

C

COP (Coefficient of Performance)
The COP indicates how much heat a heat pump generates from one kilowatt-hour of electricity: measured on a test bench, at a single operating point.

D

Continuous operation (heat pump runs non-stop)
If the heat pump runs for hours or almost continuously, this is usually normal. Warning signs are cold rooms, frequent immersion heater use and high electricity consumption.
Dynamic electricity tariff
With a dynamic electricity tariff, your energy price follows the stock exchange price. You need a smart meter for this, and the price risk lies with you.

E

Efficiency class (ErP energy label)
The EU energy label classifies heat pumps into efficiency classes. klimaaktiv recommends the highest available class at a 40 °C flow temperature.
Individual room control
With individual room control, each room regulates its own temperature. With a heat pump, its main job is to compensate for external heat gains, while the heating curve handles the rest.
Energieausweis (energy performance certificate) and heating demand (HWB)
The Heizwärmebedarf (heating energy requirement) in the Energieausweis (energy performance certificate) shows how much heat your house theoretically needs. It is a good initial indication of whether a heat pump is suitable.
Energy management system (HEMS)
A home energy management system automatically controls the heat pump, photovoltaics, storage unit and charging station, shifting consumption to cheaper times.
Geothermal basket and trench collector
Geothermal baskets and trench collectors extract geothermal energy from a smaller surface area than a horizontal ground loop. To compensate, they usually extend deeper into the ground.
Expansion valve
The expansion valve reduces the pressure of the liquid refrigerant. In doing so, it cools down and can absorb heat again in the evaporator.

F

F-Gas Regulation
EU Regulation 2024/573 gradually restricts fluorinated greenhouse gases. For new heat pumps, cut-off dates starting from 2027 apply depending on design and capacity.
Surface heating (underfloor and wall heating)
A surface heating system emits heat over large areas such as the floor or wall. It manages with low flow temperatures and is a good match for a heat pump.
Horizontal collector (ground collector)
A horizontal collector is a pipe network just below the surface of the ground, through which a geothermal heat pump extracts heat from the garden. It requires a lot of space.
Fresh water station
A fresh water station heats domestic hot water only when it is drawn off via a heat exchanger. The heat comes from a buffer cylinder containing heating water.
Frost protection (glycol and frost protection valve)
Frost protection prevents water from freezing in the heat pump's pipework. Common methods are glycol, the control unit's frost protection function, and anti-freeze valves.

G

GWP (Global Warming Potential)
The GWP value shows how much a refrigerant contributes to global warming if it escapes. CO2 has a value of 1; the lower, the better.

H

Heat Pump Keymark
The Heat Pump Keymark is a voluntary European certificate. Independent bodies verify whether a heat pump's performance specifications are accurate.
Heating threshold temperature
The heating threshold (Heizgrenze) is the outside temperature below which a house needs to be heated. In Austria, 12 °C is usually assumed, but it varies for each house.
Heating curve
The heating curve determines how warm the heating water should be at a given outdoor temperature. Correctly adjusted, it saves electricity while maintaining the same level of comfort.
Heating load
The heating load is the output in kilowatts that your house needs on the coldest day. The heat pump is sized according to this, not according to the old boiler.
Heating element (electric auxiliary heater)
The heating element is an auxiliary electric heater in the cylinder or appliance. It kicks in on very cold days, but only produces 1 kWh of heat from 1 kWh of electricity.
Heating water (water quality)
Heating water circulates in a closed circuit for years. Its quality plays a key role in preventing corrosion, limescale, sludge, and extending the system's lifespan.
Calorific value (converting fuel into kWh)
The calorific value tells you how many kilowatt-hours are contained in a litre of oil or kilogram of pellets. This lets you compare your consumption with a heat pump.
High-temperature heat pump
A high-temperature heat pump delivers higher flow temperatures than standard systems, for instance for older buildings with radiators. However, this comes at the expense of efficiency.
Hybrid heating system (heat pump with boiler)
A hybrid heating system combines a heat pump with a second heat generator, such as a pellet boiler. This is particularly useful at high flow temperatures.
Low-loss header
A hydraulic separator decouples the heat pump circuit from the heating circuits. It solves flow volume issues, but can mix the flow and return.
Hydraulic balancing
During hydraulic balancing, each heating circuit is adjusted so that it receives exactly the required amount of water. This allows for a lower flow temperature.

I

Inverter and power modulation
A modulating heat pump continuously adjusts its output to demand, usually via an inverter. This is more efficient than simply switching on and off.

J

Seasonal Performance Factor (SPF)
The seasonal performance factor shows how much heat your heat pump delivers over the entire year per kilowatt-hour of electricity. It is the most important key figure.

K

Refrigerant
The refrigerant is the substance that evaporates and liquefies again inside the heat pump, thereby transporting the heat from the source into the house.
Cascade (multiple heat pumps)
In a cascade system, several heat pumps work together as a single system. This provides greater flexibility and reliability, especially in large buildings.
Combi storage tank and hygiene storage tank
Combination and hygiene storage tanks keep heat for space heating and domestic hot water in a single vessel. For heat pumps, klimaaktiv usually advises other solutions.
Cooling with the heat pump
Many heat pumps can also cool in summer: passively via the ground or groundwater, or actively with the compressor running.

L

Legionella protection cycle
The anti-legionella cycle regularly heats the hot water cylinder to a higher temperature to kill off germs. You can clarify with your installer how often this is useful.
Air-to-air heat pump
An air-to-air heat pump extracts heat from the outside air and releases it directly into the indoor air. In most cases, this is a split air conditioning unit with a heating function.
Air-to-water heat pump
The air-to-water heat pump uses the outdoor air as a heat source to heat the heating water. It is the easiest type of heat pump to install.

M

Monobloc heat pump
With a monobloc heat pump, the entire refrigerant circuit is located in the outdoor unit. Only water pipes lead into the house, not refrigerant lines.
Monovalent, monoenergetisch, bivalent
The operating mode indicates whether the heat pump heats alone, an immersion heater kicks in, or a second heating system such as a boiler assists.

N

Night setback
With a night setback, the system heats less at night. With a heat pump, this usually brings little benefit because reheating in the morning reduces efficiency.
Low-temperature radiator
Low-temperature radiators emit enough heat even at low flow temperatures. It is often sufficient to replace individual critical radiators.
Design outdoor temperature
The design outdoor temperature is the cold rating used to calculate the heating load of your house. In Austria, it is fixed for each location.

P

Photovoltaic self-consumption with a heat pump
With a heat pump, you can use more of your own solar power yourself, especially for hot water. In the depths of winter, however, PV only covers a small portion.
Test point A7/W35
A7/W35 means: tested at 7 °C outdoor air and 35 °C heating water. The value shows a single operating point, not efficiency over the course of the year.
Buffer tank
A buffer cylinder is a water tank for heating water. With modern, modulating heat pumps in detached houses, it is often not needed at all.

R

R290 (propane)
R290 is propane used as a natural refrigerant. It has a very low global warming potential, but is flammable and therefore requires safety precautions.
R32 (refrigerant)
R32 is a fluorinated refrigerant with a GWP of 675. In many new heat pumps, it will no longer be permitted from 2027 due to EU rules.
Seasonal space heating energy efficiency (ηs)
ηs is the standardised heating efficiency over a heating season, expressed as a percentage. Because electricity generation is factored in, it is over 100%.
Return temperature
The return temperature is the temperature of the heating water flowing back to the heat pump from the radiators or underfloor heating.

S

Sound pressure level
The sound pressure level is the volume that reaches a specific location, such as the property boundary. It decreases with distance from the heat pump.
Sound power level
The sound power level indicates how much noise the heat pump itself emits, regardless of the location. It is listed in the data sheet and is suitable for comparison.
SCOP (seasonal coefficient of performance)
The SCOP is a standardised seasonal coefficient of performance for a standard climate. It is suitable for comparing devices, but does not tell you what your system will actually achieve.
SG-Ready
SG-Ready is a label for heat pumps with an interface through which they can process signals from the PV system, energy manager or grid.
Brine-to-water heat pump (geothermal energy)
The brine-to-water heat pump extracts heat from the ground via probes or collectors. It is more efficient than an air-source heat pump, but more complex.
Grid operator blocking times
With an interruptible heat pump tariff, the grid operator is allowed to temporarily switch off the heat pump. The system must be able to bridge these pauses.
Split heat pump
A split heat pump consists of an outdoor and an indoor unit connected by refrigerant lines. Installation requires specialist knowledge of refrigeration technology.
Temperature differential (spread)
The spread is the difference between flow and return temperature. It shows how much the heating water cools down in the house.

T

Cycling
Cycling means that the heat pump frequently switches on and off for short periods. This reduces efficiency and lifespan, and often indicates that the unit is too large.
Deep drilling (geothermal probe)
With deep drilling, a geothermal probe is inserted vertically into the ground. It requires little surface area and provides consistent heat all year round.

U

U-value
The U-value shows how much heat is lost through a building element. The lower it is, the better the wall, roof or window insulates.
Circulation pump
The circulating pump moves the heating water through pipes and heating surfaces. Modern, controlled pumps adjust automatically and use little electricity.

V

Evaporator
In the evaporator, the liquid refrigerant absorbs heat from air, ground or groundwater and turns into gas. It is the heat exchanger on the source side.
Compressor
The compressor increases the pressure of the gaseous refrigerant. This raises its temperature to a usable level.
Condenser
In the condenser, the hot refrigerant gas transfers its heat to the heating water, turning back into a liquid in the process.
Flow rate
The flow rate indicates how much heating water flows through the system per hour. The heat pump requires a minimum volume, otherwise it will not run properly.
Flow temperature
The flow temperature is the temperature of the heating water on its way to the heating surfaces. The lower it is, the more efficiently the heat pump operates.

W

Heat meter
A heat meter measures how much heat your heat pump delivers. Together with the electricity meter, this allows you to determine the actual seasonal performance factor (SPF).
Heat pump tariff
A heat pump tariff is a dedicated electricity tariff for the heat pump, often via an interruptible metering point. Whether it is worth it is a matter of calculation.
Hot water cylinder (boiler)
The hot water cylinder stores heated drinking water. It should be as large as necessary and as small as possible to keep heat losses to a minimum.
Heat pump maintenance
A heat pump requires little maintenance, but regular checks. For fluorinated refrigerants, a leak check may be mandatory.
Water-to-water heat pump (groundwater)
The water-to-water heat pump uses groundwater as a heat source. It is highly efficient, but requires wells and a water rights permit.
Wasserrechtliche Bewilligung (water rights permit)
Anyone using groundwater for a heat pump requires a wasserrechtliche Bewilligung (water rights permit). Geothermal energy is only affected in certain cases, in which case a notification is required.
Weather-compensated control
The weather-compensated control system adjusts the flow temperature according to the outside temperature. To do this, it requires an outdoor sensor and a heating curve.