What your device must be able to do to receive a public subsidy
A quote is on the table, the price is right, as is the timeframe. Whether the device is eligible for a public subsidy often only becomes clear during application, and by then it's unpleasant.
Yet this can be checked beforehand. The Austrian public subsidy guidelines differ significantly in amounts and deadlines, but three requirements appear almost everywhere. If you know them, you can cross-check a quote yourself in five minutes.
1. The criteria of the EHPA Quality Label
Tyrol, Vorarlberg and Burgenland require "compliance with the EHPA Quality Label criteria" in their guidelines, and all three add the same clause: confirmed by an independent testing institute.
The EHPA Quality Label is a European quality mark for electrically operated heat pumps. Behind it are minimum values for efficiency, requirements for documentation and customer service, as well as verified measurements – verified by someone other than the manufacturer itself.
The exact wording is important: the criteria are required, not the label itself. A unit with a valid quality label generally fulfils them, so the label is the easiest proof. If a unit does not have a label, it is not automatically excluded, but it will need a test report from an independent institute.
It is not entirely uniform: Upper Austria explicitly accepts both the label or compliance with its criteria. Lower Austria, on the other hand, requires the label itself plus a type test for the renovation grant (Sanierungsförderung).
For you, this means: ask about the label first. If the unit does not have one, ask for the test report – and do so before you sign.
2. The refrigerant and its global warming potential
Tyrol, Vorarlberg and Burgenland set the same limit: the refrigerant used must not exceed a GWP of 2.000. Tyrol specifies "according to the 5th IPCC Assessment Report", while Upper Austria is significantly stricter with a maximum of 750.
GWP stands for Global Warming Potential and describes how strongly a substance acts as a greenhouse gas compared to CO₂. A GWP of 2.000 means: one kilogram of this substance acts like two tonnes of CO₂ if it escapes.
In practice, this hurdle is rarely a problem for new devices. The market has shifted heavily towards low-GWP refrigerants, most notably propane (R290) with a single-digit value. The limit becomes relevant for older stock items and quotes that are suspiciously cheap.
The federal government is also significantly stricter: for the boiler replacement (Kesseltausch), according to the information sheet for the 2026 edition, the refrigerant must have a GWP of 750 at most. If the value for an air-to-water heat pump is between 150 and 750, there is 20 percent less public subsidy; this applies to monoblock units up to 50 kW and split units up to 12 kW.
If in doubt, ask about the refrigerant and have them tell you the GWP value. It is in the data sheet, and in Upper Austria it is explicitly asked for in the public subsidy form.
3. The GET product database
This is the most practical point because you can look it up yourself.
The GET database is the Austrian product database for building energy technology. Tyrol formulates its role clearly: for checking the technical requirements, "fundamentally the product declaration on the GET product database" serves as the basis.
What this means: it is not the sales pitch that decides, but the entry in the database. That is where the values used by the funding authority are listed: output, efficiency, sound power level, refrigerant.
If you are offered a specific model, look it up there before you sign. If it is not listed, that is not proof of a bad unit, but certainly a reason to clarify how proof will otherwise be provided before signing. Our overview Förderfähige Wärmepumpen (Eligible heat pumps) shows which brands and series are on the lists of the federal government, Tyrol and Vorarlberg.
What individual federal states additionally require
Beyond this common core, it becomes specific to the federal state. Two examples from the checked guidelines:
Vorarlberg also requires measuring equipment: for self-monitoring of the seasonal performance factor (Jahresarbeitszahl), "a heat meter and a dedicated electricity meter must be present". This is not a bureaucratic hurdle, but the only way to know later whether the system is actually running efficiently. Anyone installing the meters anyway benefits from it, regardless of the public subsidy.
Tyrol and others tie it to the flow temperature. How this works and what it means for your house can be found in the article about the flow temperature.
⚠️ This list is no substitute for checking the guidelines of your federal state. We have examined the full text of the guidelines for Tyrol, Vorarlberg and Burgenland, as well as the subsidy pages of Upper and Lower Austria, and described the common denominator. Additional conditions may apply in the remaining states. The status for each federal state can be found in the Förderübersicht (Subsidy overview).
The short version for the quote discussion
Four questions that should be clarified before signing:
- Does the unit have the EHPA Quality Label? If not: is there a test report from an independent institute on the quality label criteria? In Lower Austria, the label itself is required.
- Which refrigerant, which GWP value?
- Is the model registered in the GET database?
- Are the heat meter and electricity meter included in the quote? Mandatory in Vorarlberg, sensible everywhere else.
Experience shows that an installer who answers these four questions with confidence works carefully in other areas as well. Evasive answers are the real signal, not the answer itself.
AO
Sources
- Land Tirol — Wohnhaussanierungsrichtlinie, edition 1.1.2026 (PDF), item 2.3.3 — retrieved on 8 November 2026
- Land Vorarlberg — Richtlinie Heizungstausch 2026 (PDF), § 7 para. 2 — retrieved on 8 November 2026
- Land Burgenland — Richtlinie Sonderförderung Heizungstausch 2026 (PDF), item 7 A — retrieved on 8 November 2026
- Land Oberösterreich — Förderprogramm für Wärmepumpen, Fernwärmeanschlüsse und thermische Solaranlagen — retrieved on 8 November 2026
- Land Niederösterreich — Ergänzungen für hocheffiziente Heizungsanlagen — retrieved on 8 November 2026
- GET-Datenbank — Produktdatenbank Gebäude-Energie-Technik — retrieved on 8 November 2026
- Sanierungsoffensive des Bundes (Federal renovation offensive) — info sheet Kesseltausch 2026, relaunch from 02.11.2026, detached/semi-detached house/terraced house (PDF, version 10/2026) — accessed on 16 October 2026
We reproduce facts in our own words and link to the source. Public subsidy and legal information can change at short notice — the mentioned authority is always binding.