High-temperature heat pump
A high-temperature heat pump delivers higher flow temperatures than standard systems, for instance for older buildings with radiators. However, this comes at the expense of efficiency.
A high-temperature heat pump refers to units designed for higher flow temperatures than the 55 °C up to which klimaaktiv classifies a house as suitable without further measures. We are not aware of any uniformly defined threshold. The Energieinstitut Vorarlberg notes that current devices can provide over 60 °C. So check which temperature is meant in the quote.
Why this is important
According to the Energieinstitut Vorarlberg, the coefficient of performance drops drastically with increasing flow temperature, even in devices with adapted refrigerants. A comparison of options in the German dena guide for a partially renovated multi-family building showed a seasonal performance factor of 3.0 at a maximum of 70 °C, and 3.2 at 60 °C.
What this means for you
- Test in winter how far you can lower the flow temperature. If all rooms stay warm with a maximum of 55 °C, your house is suitable without further measures according to klimaaktiv.
- Replace radiators specifically in critical rooms. Often, low-temperature radiators in just a few locations are sufficient.
- Check simple steps such as insulating the top floor ceiling and hydraulic balancing.
- If the temperature remains high, also have a hybrid heating system calculated.
You can read more about this under Flow temperature. The suitability check gives you a first assessment.
Related terms
Flow temperatureLow-temperature radiatorHybrid heating system (heat pump with boiler)Seasonal performance factor (SPF/JAZ)
Sources
- Energieinstitut Vorarlberg: How can heat pumps be operated efficiently in existing buildings? (retrieved on 4 November 2026)
- klimaaktiv: Heat pumps – how the switch works (retrieved on 4 November 2026)
- dena: Practical guide for heat pumps in multi-family residential buildings (2024) (retrieved on 4 November 2026)