Night setback

With a night setback, the system heats less at night. With a heat pump, this usually brings little benefit because reheating in the morning reduces efficiency.

Night setback means that the control system lowers the temperature for a few hours, usually via a timed schedule. At night, the heating runs with a lower flow temperature, and in the morning, the house is heated up again.

Why this is important

With a heat pump, every degree of flow temperature counts. The energy advisory service of the City of Zurich calculates it like this: without setback, the flow temperature can be lowered by around 2 °C during the day and kept constant. Although it is higher at night, bottom line the heat pump operates more efficiently. Energieberatung NÖ (Lower Austria Energy Advisory Service) also advises against night setback with heat pumps, except during the shoulder seasons.

For heating systems in general, the Energieinstitut Vorarlberg sees things differently: it calls the claim that reheating takes more energy than was saved overnight a myth. However, it also notes that in new, well-insulated houses, the effect is minimal because the temperature hardly drops at all.

What this means for you

  • Testing: Turn off the setback, gradually lower the heating curve and compare electricity consumption over several weeks.
  • Immersion heater: If it kicks in during the morning, an excessively large setback could be the reason.
  • Underfloor heating: It reacts slowly because the screed retains heat.
  • Exceptions: With a tariff offering cheaper off-peak windows, different rules may apply – see dynamic electricity tariff.

You can find further settings under After installation.

All terms · Heat pump knowledge