Spread (temperature difference)

The spread is the difference between flow and return temperature. It shows how much the heating water cools down in the house.

The heating water leaves the heat pump at the flow temperature and returns at the return temperature. The difference is called the temperature spread. Specialists express it in Kelvin, where 1 K corresponds to 1 °C. With a flow temperature of 40 °C and a return temperature of 30 °C, the temperature spread is therefore 10 K.

Why this is important

The required water volume is determined by heating output and temperature spread. The smaller the temperature spread, the more water must flow for the same amount of heat. That is the flow rate. The klimaaktiv Leitfaden zum hydraulischen Abgleich (guideline on hydraulic balancing) recommends a spread of 20 °C for standard heating systems, and 10 °C for heat pumps and underfloor heating. The Bundesverband Wärmepumpe (German Heat Pump Association) suggests 5 to 7 K under design conditions, depending on the system layout, and up to a maximum of 10 K for radiators. So there is no single right value.

What this means for you

  • Taking a reading: Ask your installer where you can see the flow and return temperatures, and note down both values on a cold day.
  • Switching from a boiler: If the temperature spread is reduced from 20 to 10 K, the water volume and pressure loss increase. According to the guide, this can cause rushing noises in the radiator valves. A new hydraulic balancing is required as part of the process.
  • Unequal values: According to Energieberatung NÖ (Lower Austria Energy Advisory Service), it is a sure sign of missing balancing if a radiator close to the pump has a very small spread and a distant one has a very large spread.

The target value can be found in the system design and manufacturer specifications. You can read about how balancing should look in the quote under Checking quotes.