U-value

The U-value shows how much heat is lost through a building element. The lower it is, the better the wall, roof or window insulates.

The U-value is also called the thermal transmittance coefficient, formerly k-value. It indicates how well or poorly a building component conducts heat, such as the facade, top floor ceiling, cellar ceiling or windows. The unit is W/(m²·K), i.e. watts per square metre and kelvin temperature difference. The smaller the number, the less heat is lost.

Why this is important

According to klimaaktiv, the U-value feeds into the Energy Performance Certificate (Energieausweis) and the heating load. For a heat pump, this counts twice: lower heat demand allows lower flow temperatures, which are the basis for low running costs.

To put this into context, the klimaaktiv factsheet cites these values:

  • External wall in an uninsulated old building: 0.60 to 2.40
  • External wall, very well renovated: 0.18 at most
  • Windows and doors in an old building: 2.50 to 4.60
  • Windows and doors, very well renovated: 0.90 at most

For new builds, OIB-Richtlinie 6 (OIB Guideline 6, September 2025 edition) specifies maximum values, for example 0.35 for walls against outside air and 1.40 for windows in residential buildings. According to klimaaktiv, the federal states can deviate from these.

What this means for you

  • Ask your energy consultant about the U-values of your building components.
  • Compare components to find where you can make the biggest impact. A component with a high U-value and a large surface area loses the most heat.
  • Plan any renovation together with your heating system, as it will change your heat demand.

You can assess how suitable your house is for a heat pump using the suitability check. The overall performance is shown by the Energy Performance Certificate (Energieausweis) and HWB.