Fresh water station
A fresh water station heats domestic hot water only when it is drawn off via a heat exchanger. The heat comes from a buffer cylinder containing heating water.
- Heat pump.
- Diverter valve: it directs the heating water either to the heating circuit or to the hot water.
- Buffer cylinder: balances out short-term differences between heat generated and heat used.
- Heating circuit with underfloor heating or radiators.
- Hot water cylinder: keeps the domestic water warm; occasionally, it is heated to a higher temperature for legionella protection.
With a fresh water station, also known as a fresh water module, the heat is not stored in domestic hot water, but in the heating water of a buffer cylinder. Only when you turn on the tap does cold domestic water flow through an external heat exchanger and get heated as it passes through. The opposite concept is the hot water cylinder, in which heated domestic water is stored.
Why this is important
The manual from the Swiss Federal Office of Energy sees the main advantage in hygiene: apart from in the pipes, hardly any hot water is stored. This allows the temperature to remain low, which benefits the heat pump. According to the klimaaktiv Ratgeber Warmwasser (hot water guide), water quality does not deteriorate during prolonged periods of disuse either. However, it is more complex than a hot water cylinder, and if there is a power cut, there is no hot water. For heat pumps, klimaaktiv advises generously sized modules or hot water cylinders.
What this means for you
- Sizing: The module must match your actual requirements. State bath, rainfall shower and number of people.
- Cylinder temperature: The smaller the temperature difference at the heat exchanger needs to be, the larger it must be. According to klimaaktiv, every additional degree in the cylinder increases losses by around 1,6 %.
- Limescale: Below 60 °C, hardly any limescale precipitation is to be expected according to klimaaktiv. The Federal Office nevertheless advises keeping an eye on limescale build-up.
- Pipework: Short distances remain important because water continues to sit there.
The version with an internal heat exchanger is described under Combi storage cylinder. For hygiene, read Legionella protection cycle.