Combination storage tank and hygiene storage tank

Combination and hygiene storage tanks keep heat for space heating and domestic hot water in a single vessel. For heat pumps, klimaaktiv usually advises other solutions.

12345
Buffer cylinder and hot water cylinder
  1. Heat pump.
  2. Diverter valve: it directs the heating water either to the heating circuit or to the hot water.
  3. Buffer cylinder: balances out short-term differences between heat generated and heat used.
  4. Heating circuit with underfloor heating or radiators.
  5. Hot water cylinder: keeps the domestic water warm; occasionally, it is heated to a higher temperature for legionella protection.
Schematic. Not every system needs a buffer cylinder.

A combi cylinder provides heat for both space heating and domestic hot water in a single tank. The cylinder contains heating water. The drinking water flows through an internal heat exchanger and is heated in the process. The klimaaktiv Hot Water Guide uses the terms combi cylinder or hygiene cylinder for such storage tanks. In a freshwater station, on the other hand, the heat exchanger is located externally.

Why this is important

This design has advantages: the heat exchanger does not need its own pump or control system, and according to the Swiss Federal Office of Energy (SFOE), it saves space compared to two separate cylinders. However, there is a catch for heat pumps. klimaaktiv notes that for high demand, such as filling a bathtub, these systems only work well if they are kept at a high temperature. This causes higher heat losses. Because heat pumps operate most efficiently at low temperatures, klimaaktiv recommends buffer cylinders with generous fresh water modules or domestic hot water cylinders. The Swiss Federal Office points to tested solutions that can also run well with heat pumps.

What this means for you

  • Justification: If a combi cylinder is listed in the quote, ask why it fits better than a hot water cylinder or freshwater station.
  • Stratification: Integration is tricky. If the temperature stratification is regularly disrupted, the energy demand increases significantly according to the Federal Office.
  • Insulation: According to klimaaktiv, energy efficiency class B is considered the minimum in a detached house.

Find out more under Check quote.

All terms · Heat pump knowledge