Seasonal space heating energy efficiency (ηs)

ηs is the standardised heating efficiency over a heating season, expressed as a percentage. Because electricity generation is factored in, it is over 100%.

ηs (pronounced 'Eta s') is referred to in Regulation (EU) No 813/2013 as seasonal space heating energy efficiency. The η stands for efficiency, the small s for the heating season. The value is given as a percentage. The basis is the SCOP, divided by the conversion coefficient CC = 2,5. This factor represents an estimated electricity generation efficiency of 40 % in the EU. Added to this are corrections for temperature control, and for water and brine units also for the groundwater pump. A SCOP of 4,0 therefore gives 160 %, before these corrections.

Why this is important

The regulation specifies minimum values: 110 % for heat pumps, 125 % for low-temperature heat pumps. At a flow temperature of 40 °C, the klimaaktiv guide recommends more: over 180 % for air, over 200 % for ground and over 230 % for groundwater.

It is calculated for average climate conditions, according to the regulation those of Strasbourg, with -10 °C as the design temperature. ηs says nothing about your house. Only the seasonal performance factor shows that.

What this means for you

  • Only compare values at the same temperature, i.e. 35 °C with 35 °C and 55 °C with 55 °C.
  • If your heating system is only suitable for higher flow temperatures, look at the value at 55 °C.
  • 180 % does not mean that 1 kWh of electricity becomes 1,8 kWh of heat. Before corrections, this corresponds to an SCOP of around 4,5.

In the Heat pump comparison you can see ηs per unit; the values come from the EU product database EPREL. The classes are explained under Efficiency class.

All terms · Heat pump knowledge